==[[/Vendors|Vendors]]== | |||
== CPU Power Measurement Resources == | |||
*[http://forumz.tomshardware.com/hardware/measure-CPU-power-ftopict201295.html CPU power measurement, online conversaion] | *[http://forumz.tomshardware.com/hardware/measure-CPU-power-ftopict201295.html CPU power measurement, online conversaion] | ||
| Line 12: | Line 12: | ||
==[http://www.keithly.com/products/dmm/?path=2000/Documents#4 Keithly 2000 Digital Multimeter] == | |||
<sup>(in use by Vibhu at Intel)</sup> | |||
*The Model 2000 can make DCV measurements from 0.1μV to 1000V and ACV | *The Model 2000 can make DCV measurements from 0.1μV to 1000V and ACV | ||
measurements from 0.1μV to 750V RMS, 1000V peak. This is a 6.5 digit DMM. | measurements from 0.1μV to 750V RMS, 1000V peak. This is a 6.5 digit DMM. | ||
| Line 18: | Line 19: | ||
*[http://www.esoterum.org/mw/images/9/99/KeithlyMMSpec%2C2000RevF_DocSpec_2000_Specifications-1-.pdf Keithly 2000 spec sheet (loaded to the wiki)] | *[http://www.esoterum.org/mw/images/9/99/KeithlyMMSpec%2C2000RevF_DocSpec_2000_Specifications-1-.pdf Keithly 2000 spec sheet (loaded to the wiki)] | ||
== [http://www.home.agilent.com/agilent/editorial.jspx?cc=US&lc=eng&ckey=579458&nid=-536900126.0.00&id=579458 Agilent DAQ Cards] == | |||
*1-800-829-4444 | *1-800-829-4444 | ||
*BNC vs. 37-pin D-type connectors | *BNC vs. 37-pin D-type connectors | ||
| Line 33: | Line 34: | ||
*60 day return policy, educational discount | *60 day return policy, educational discount | ||
== [http://www.keithley.com/products/dataacqmodules/view Keithly DAQ Cards] == | |||
== [http://www.ni.com/dataacquisition/usb/ National Instruments DAQ Cards] == | |||
*[http://www.ni.com/pdf/products/us/niusb9215a.pdf NI USB-9215A] | *[http://www.ni.com/pdf/products/us/niusb9215a.pdf NI USB-9215A] | ||
::16bit, 100kS/s, available with BNC connectors | ::16bit, 100kS/s, available with BNC connectors | ||
Revision as of 17:16, 8 March 2007
Vendors
CPU Power Measurement Resources
Keithly 2000 Digital Multimeter
(in use by Vibhu at Intel)
- The Model 2000 can make DCV measurements from 0.1μV to 1000V and ACV
measurements from 0.1μV to 750V RMS, 1000V peak. This is a 6.5 digit DMM.
Agilent DAQ Cards
- 1-800-829-4444
- BNC vs. 37-pin D-type connectors
- Number of channels: single-ended (SE) or differential analog (DI)
8 March 2007, Conversation with Agilent sales rep
- 1 (800) 829-4444, Sales rep in Denver
- Pete (technical representative)

- DAQ uses a 68 pin connector (SCSI-II 68pin)
- Use a "terminal board" which connects to the 68 pin connector
- U2901A 1m cable $123
- U2902A 2m cable $144
- 60 day return policy, educational discount
Keithly DAQ Cards
National Instruments DAQ Cards
- 16bit, 100kS/s, available with BNC connectors